BEM LINA Ersatzfilter
Finden Sie passende BEM LINA Ersatzfilter für die regelmäßige Wartung Ihrer Wasserfilteranlage. Für das mehrstufige Filtersystem stehen je nach Ausführung einzelne Filterkartuschen sowie komplette Filtersets zur Verfügung.
Wählen Sie den benötigten PAC-, RO-, CF- beziehungsweise SR-Filter passend zu Ihrer BEM LINA und achten Sie vor der Bestellung auf die angegebene Modell- und Produktkompatibilität.
CF replacement filter for BEM Lina and BEM Ida water filters - third purification stage
CF replacement filter for BEM Lina and BEM Ida water filters - third purification stage Final purification based on pressed activated carbon without mineral fillers. Improves the taste of the water, removes residual odours and stabilizes the quality of the drinking water after the membrane. Properties: Contains no mineral additives and no mineralizing components. Used to purify water after the reverse osmosis membrane. Improves the taste of the water, removes residual odors and foreign tastes. Stabilizes the quality of drinking water after depth filtration and makes the taste softer and more neutral. Ø 6.8 x 29.2 cm Weight: 0.48 kg Replacement interval: Replace the filter cartridge every 6-12 months (depending on the water quality) Please note: Instead of the standard carbon after-filter, an SR remineralization filter (item no. 70200605) can be installed in the system. It performs the same post-cleaning functions, but additionally enriches the water with 18 natural minerals (calcium, magnesium, potassium, etc.) and thus ensures a soft and balanced composition.Important! The post-filter does not clean the water of impurities - it only affects the taste. If worn, it does not protect against odors. The service life depends on the quality of the initial water and the consumption volume. A delayed filter change can lead to a deterioration in the taste of the water. Recommendations for filter change according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (CF/SR) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
PAC replacement filter for BEM Lina and BEM Ida water filters - first cleaning stage
PAC replacement filter for BEM Lina and BEM Ida water filters - First cleaning stage Features: Foldable combined polypropylene/cotton cartridge with activated carbon Removal of impurities such as sediment, rust, sand, suspended particles Reduces chlorine content, eliminates odors and foreign tastes. Replacement interval: Replace the filter cartridge every 6-12 months (depending on the water quality)Important! The service life depends on the quality of the tap water and the consumption volume. Delayed replacement can lead to a reduction in the efficiency of the entire system and damage to the membrane. The use of filters with hot water (>38°C) is prohibited, as this destroys the structure of the membrane and the activated carbon Recommendations for filter replacement according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (CF/SR) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
RO replacement filter for BEM Lina and BEM Ida water filters - second purification stage
RO replacement filter for BEM Lina and BEM Ida water filters - second purification stage Features: Main element of reverse osmosis filtration. Ensures deep purification of the water at molecular level. The membrane with a pore size of 0.0001 μm retains up to 99 % of dissolved substances. Removes hardness salts, heavy metals, bacteria, impurities and dissolved substances (TDS). Replacement interval: Replace the filter cartridge every 12-24 months (depending on the water quality) Important! The service life of the cartridges depends on the quality of the source water and the volume used. Delayed replacement of the pre-filter (1st stage, PAC) can impair the function of the reverse osmosis membrane (RO). Ignoring the membrane change can lead to impurities entering the drinking water and to a reduction in the efficiency and functionality of the appliance. Recommendations for filter change according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (CF/SR) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
Set of 3 replacement filters (RO+PAC+CF) for BEM LINA and IDA water filters
Set of 3 replacement filters (RO+PAC+CF) for BEM LINA and IDA water filters Complete set of three filter elements for multi-stage water treatment: pre-filtration, deep cleaning and final taste improvement. 1st stage - PAC (pre-filter): Combined filter made of polypropylene/cotton and activated carbon. Removes / reduces: Sand, rust and deposits mechanical and suspended particles residual chlorine Unpleasant odors and flavors Change interval: 6-12 months (depending on the quality of the tap water, e.g. water hardness) 2nd stage - RO (reverse osmosis): Membrane filter for deep water purification. Enables filtration at molecular level. Filtration fineness: up to 0.0001 µm Removes / reduces: dissolved substances (TDS) Hardness salts heavy metals Organic and inorganic impurities Replacement interval: up to 12 months (depending on the quality of the tap water, e.g. water hardness) 3rd stage - CF (secondary filter): Activated carbon filter for final water treatment: improves taste and odor removes residual substances remaining after the membrane Replacement interval: 6-12 months (depending on the quality of the tap water, e.g. water hardness)Important! The service life of the filter depends on the quality of the source water and the intensity of use. More frequent replacement may be necessary if the load is higher. Failure to replace the filter in good time can impair its performance and cause damage to the membrane. Use with hot water (>38°C) is not permitted as this can damage the structure of the membrane and the activated carbon. Recommendations for filter replacement according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (CF) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
Set of 3 replacement filters (RO+PAC+SR) for BEM Lina and BEM Ida water filters
Set of 3 replacement filters (RO+PAC+SR) for BEM LINA and IDA water filters Complete set of three filter elements for multi-stage water treatment: pre-filtration, deep cleaning and final taste improvement. 1st stage - PAC (pre-filter): Combined filter made of polypropylene/cotton and activated carbon. Removes / reduces: Sand, rust and deposits mechanical and suspended particles residual chlorine Unpleasant odors and flavors Change interval: 6-12 months (depending on the quality of the tap water, e.g. water hardness) 2nd stage - RO (reverse osmosis): Membrane filter for deep water purification. Enables filtration at molecular level. Filtration fineness: up to 0.0001 µm Removes / reduces: dissolved substances (TDS) Hardness salts heavy metals Organic and inorganic impurities Change interval: up to 12 months (depending on the quality of the tap water, e.g. water hardness) 3rd stage - SR (remineralization): Post-filter with remineralization function. Improves the taste of the water and enriches it with important minerals. Enriches the water with: Calcium magnesium potassium sodium Additionally: improves the taste Stabilizes the water composition Change interval: 6-12 months (depending on the quality of the tap water, e.g. water hardness)Important! The service life of the filter depends on the quality of the source water and the intensity of use. More frequent replacement may be necessary if the load is higher. Failure to replace the filter in good time can impair its performance and cause damage to the membrane. Use with hot water (>38°C) is not permitted as this can damage the structure of the membrane and the activated carbon. Recommendations for filter replacement according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (SR) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
SR remineralization replacement filter for BEM Lina and BEM Ida water filters - 3rd stage
SR remineralization replacement filter for BEM Lina and BEM Ida water filters - third purification stage SR remineralization filter - final filtration stage for BEM Lina / Ida water filters. Installed after the reverse osmosis membrane for additional water treatment. Features: Used in the final filtration stage to remineralize the water and improve the taste. Restores the taste and natural balance of the water after deep purification. Contains a mineral blend that enriches the water with calcium, magnesium, potassium, sodium, zinc, strontium and other elements. Ensures a soft and balanced mineralization at a level of about 30-60 ppm. Ø 6.8 x 29.2 cm Weight: 0.48 kg Replacement interval: Replace the filter cartridge every 6-12 months (depending on the water quality)Important! The after-filter does not clean the water of impurities - it only affects the taste. If worn, it does not protect against odors. The service life depends on the quality of the initial water and the consumption volume. A delayed filter change can lead to a deterioration in the taste of the water. Recommendations for filter change according to TDS value: TDS value (ppm) Water quality 1st stage (PAC) 2nd stage (RO) 3rd stage (CF/SR) 0-150 Soft 12 months 24 months 12 months 150-300 medium hard 9-12 months 18-24 months 9-12 months 300-500 hard 6-9 months 12-18 months 6-9 months 500+ very hard 4-6 months 12 months 4-6 months The specified lifetimes are guide values and are based on average water consumption (approx. 10-20 liters per day) and the quality of the source water. With an increased TDS value and a higher degree of contamination, the service life of the filters can be shortened even with a relatively low usage volume. GPSR-Informationen Verantwortliche PersonFirma: Bem GmbHLand: DeutschlandStadt: LöhneStraße: Oeynhausener Str. 54Postleitzahl: 32584E-Mail: post@bemshop.de
Welche Ersatzfilter benötigt die BEM LINA?
Die BEM LINA arbeitet mit einem mehrstufigen Filterkonzept. Die einzelnen Filter übernehmen unterschiedliche Aufgaben innerhalb der Wasseraufbereitung und sollten deshalb nicht miteinander verwechselt werden.
Was macht der PAC-Filter der BEM LINA?
Der PAC-Filter bildet die erste Reinigungsstufe und bereitet das Rohwasser für die nachfolgende RO-Membran vor.
Dabei können mechanische Vorfiltration und Aktivkohle innerhalb einer kombinierten Filterkartusche miteinander verbunden sein.
Die Vorfiltration ist besonders wichtig, weil sie die nachfolgenden Komponenten des Systems entlastet.
Was macht die RO-Membran der BEM LINA?
Die RO-Membran ist die zentrale Membranstufe der BEM LINA. Das Wasser wird unter Druck durch eine semipermeable Membran geführt.
Dabei wird ein aufbereiteter Wasserstrom vom Konzentratstrom getrennt. Umkehrosmose besitzt ein breites Rückhaltespektrum für zahlreiche gelöste Salze und Ionen.
Die konkrete Reduktionsleistung für einzelne Stoffe hängt jedoch von Membran, Stoffeigenschaften und Betriebsbedingungen ab.
Mehr zur Technik erfahren Sie unter „Wie funktioniert eine Osmoseanlage?“ .
Was macht der CF-Nachfilter?
Der CF-Filter wird nach der RO-Membran eingesetzt und basiert auf Aktivkohle.
Seine Aufgabe liegt insbesondere in der geschmacklichen Nachbehandlung des bereits aufbereiteten Wassers.
Er sollte deshalb nicht mit der eigentlichen Umkehrosmosemembran gleichgesetzt werden.
Was ist der Unterschied zwischen CF und SR?
CF und SR sind unterschiedliche Nachfiltervarianten. Welche Variante verwendet werden soll, hängt von der gewünschten beziehungsweise für das Gerät vorgesehenen Konfiguration ab.
Prüfen Sie deshalb vor der Bestellung die genaue Produktbeschreibung des jeweiligen Filters.
Wichtig:
CF und SR sollten nicht allein aufgrund ihrer Position
im Filtersystem als identische Filter betrachtet werden.
Verwenden Sie die für Ihre gewünschte LINA-Konfiguration
vorgesehene Filterkartusche.
Einzelfilter oder komplettes LINA Filterset?
Ob Sie einzelne Filter oder ein komplettes Filterset benötigen, hängt davon ab, welche Wartung aktuell ansteht.
Wie oft müssen BEM LINA Filter gewechselt werden?
Die verschiedenen Filterstufen besitzen nicht zwangsläufig dieselbe vorgesehene Nutzungsdauer.
Einfluss auf die tatsächliche Beanspruchung können unter anderem haben:
- Rohwasserqualität,
- Wasserverbrauch,
- verarbeitetes Wasservolumen,
- Filtertyp,
- Betriebsbedingungen,
- regelmäßige Wartung der vorgelagerten Filterstufen.
Maßgeblich ist deshalb das für den jeweiligen BEM LINA Ersatzfilter angegebene Wechselintervall.
Warum ist der rechtzeitige Wechsel des Vorfilters wichtig?
Die Vorfilterstufe bereitet das Rohwasser für die nachgeschaltete RO-Membran vor.
Wird ein Vorfilter deutlich über seine vorgesehene Nutzungsdauer hinaus betrieben, kann dies abhängig von Wasserqualität und Systemzustand die nachfolgenden Filterkomponenten stärker beanspruchen.
Deshalb sollten Vorfilter und RO-Membran als aufeinander abgestimmte Bestandteile eines Gesamtsystems betrachtet werden.
Muss die RO-Membran gleichzeitig mit PAC und CF gewechselt werden?
Nicht zwangsläufig.
Vorfilter, Nachfilter und RO-Membran können unterschiedliche Wartungsintervalle besitzen.
Ein Filterset ist daher besonders praktisch, wenn die enthaltenen Komponenten laut Wartungsplan gemeinsam ersetzt werden sollen.
Kann ein TDS-Messgerät den Filterwechsel bestimmen?
Ein TDS- beziehungsweise EC-Messgerät kann die Veränderung der elektrischen Leitfähigkeit zwischen Roh- und Reinwasser orientierend sichtbar machen.
Daraus lässt sich jedoch nicht zuverlässig ableiten, wie stark beispielsweise der PAC- oder CF-Aktivkohlefilter bereits beladen ist.
Einzelne Stoffe wie PFAS, Pestizide oder Medikamentenrückstände können mit einem TDS-Gerät ebenfalls nicht spezifisch bestimmt werden.
Mehr dazu erfahren Sie unter „TDS-Wert erklärt“ .
Wie werden die BEM LINA Ersatzfilter gewechselt?
Der Filterwechsel sollte entsprechend der Bedienungs- und Wartungsanleitung der BEM LINA durchgeführt werden.
Grundsätzlich können dabei je nach Filterwechsel unter anderem folgende Schritte erforderlich sein:
- Gerät ordnungsgemäß außer Betrieb nehmen.
- Stromversorgung gegebenenfalls trennen.
- Wasser entsprechend der Anleitung entleeren beziehungsweise absperren.
- Benötigte Filterkartusche entnehmen.
- Neuen kompatiblen Filter korrekt einsetzen.
- Filteranzeige gegebenenfalls zurücksetzen.
- Vorgesehenen Spülvorgang durchführen.
- Gerät wieder bestimmungsgemäß in Betrieb nehmen.
Die konkrete Vorgehensweise kann je nach Filterposition und Geräteversion abweichen.
Müssen neue LINA Filter gespült werden?
Je nach Filterkartusche kann nach dem Einbau ein definierter Spülvorgang erforderlich sein.
Die dafür vorgesehene Vorgehensweise sollte vollständig nach der jeweiligen Produkt- beziehungsweise Geräteanleitung durchgeführt werden.
Passen BEM LINA Filter auch zur BEM IDA?
Einzelne Filterkomponenten können für mehrere BEM AQUA Modelle vorgesehen sein. Daraus sollte jedoch keine allgemeine Austauschbarkeit aller LINA- und IDA-Filter abgeleitet werden.
Entscheidend ist immer die Kompatibilitätsangabe beim jeweiligen Ersatzfilter.
Warum ist die Artikelnummer wichtig?
Modellname und Filterbezeichnung sind wichtige Orientierungspunkte. Die Artikelnummer ermöglicht zusätzlich eine eindeutige Zuordnung der benötigten Filterkomponente.
Besonders bei ähnlichen Filtervarianten sollte deshalb vor der Bestellung auch die Artikelnummer geprüft werden.
Mehr über die BEM LINA erfahren
Informationen zur kompletten Anlage finden Sie auf der Produktseite der BEM LINA .
Ersatzfilter für weitere BEM AQUA Modelle finden Sie in unserer Ersatzfilter-Übersicht .
BEM LINA Ersatzfilter kaufen
Prüfen Sie zunächst, welche Filterstufe bei Ihrer BEM LINA aktuell gewechselt werden muss.
Wählen Sie anschließend den passenden PAC-, RO-, CF- beziehungsweise SR-Filter oder ein für Ihre Wartung geeignetes Filterset.
So ersetzen Sie gezielt die benötigten Komponenten, ohne unnötig funktionsfähige Filterstufen auszutauschen.
Häufige Fragen zu BEM LINA Ersatzfiltern
Welche Ersatzfilter gibt es für die BEM LINA?
Für die BEM LINA stehen je nach Konfiguration unter anderem PAC-, RO-, CF- beziehungsweise SR-Filter sowie passende Filtersets zur Verfügung.
Welche Filterstufe ist der PAC-Filter?
Der PAC-Filter wird als Vorfilterstufe vor der Umkehrosmosemembran eingesetzt.
Welche Filterstufe ist der RO-Filter?
Der RO-Filter enthält die Umkehrosmosemembran und bildet die zentrale Membranstufe der BEM LINA.
Welche Filterstufe ist der CF-Filter?
Der CF-Filter wird nach der RO-Membran eingesetzt und dient als Aktivkohle-Nachfilter insbesondere der geschmacklichen Nachbehandlung.
Was ist der Unterschied zwischen CF und SR?
Es handelt sich um unterschiedliche Nachfiltervarianten. Welche Ausführung für Ihre gewünschte Konfiguration vorgesehen ist, sollte anhand der jeweiligen Produktbeschreibung geprüft werden.
Gibt es ein komplettes BEM LINA Filterset?
Ja. Für die BEM LINA sind auch Filtersets erhältlich, die mehrere für das System vorgesehene Filterstufen kombinieren.
Muss ich alle LINA Filter gleichzeitig wechseln?
Nicht zwangsläufig. Die einzelnen Filterstufen können unterschiedliche vorgesehene Wechselintervalle besitzen.
Wie oft muss der PAC-Filter gewechselt werden?
Maßgeblich ist das beim konkreten Ersatzfilter angegebene Wartungsintervall. Wasserqualität und Nutzungsintensität können die tatsächliche Beanspruchung beeinflussen.
Wie oft muss die RO-Membran gewechselt werden?
Die RO-Membran besitzt ein eigenes Wartungsintervall, das sich von den Vor- und Nachfiltern unterscheiden kann. Maßgeblich sind die Angaben zum konkreten Ersatzfilter.
Wie oft muss der CF-Filter gewechselt werden?
Auch für den CF-Nachfilter sollte das vorgesehene produktspezifische Wechselintervall eingehalten werden.
Kann ich den Filterzustand mit TDS bestimmen?
Nicht vollständig. TDS beziehungsweise EC kann Veränderungen gelöster ionischer Stoffe orientierend darstellen, bestimmt aber beispielsweise nicht die verbleibende Adsorptionskapazität eines Aktivkohlefilters.
Müssen neue Filter gespült werden?
Je nach Filterkomponente kann ein Spülvorgang erforderlich sein. Maßgeblich sind die Anweisungen des jeweiligen Ersatzfilters und der BEM LINA.
Muss nach dem Filterwechsel die Anzeige zurückgesetzt werden?
Wenn die Geräteversion eine elektronische Filterüberwachung verwendet, kann nach dem Austausch ein entsprechender Reset erforderlich sein.
Passen BEM IDA Filter auch in die BEM LINA?
Einzelne Filter können für beide Modelle freigegeben sein. Eine generelle Austauschbarkeit aller Filter sollte daraus jedoch nicht abgeleitet werden. Entscheidend ist die jeweilige Kompatibilitätsangabe.
Kann ich einen Filter eines anderen Herstellers verwenden?
Entscheidend ist die nachgewiesene technische Kompatibilität mit der BEM LINA. Gleiche Abmessungen oder ein ähnliches Erscheinungsbild allein reichen nicht aus.
Wo finde ich Ersatzfilter für andere BEM AQUA Modelle?
Ersatzfilter für weitere Geräte finden Sie in der BEM AQUA Ersatzfilter-Übersicht .
Mehr Wissen zu Filtern und Umkehrosmose
Erfahren Sie, welche Aufgaben Vorfilter, Aktivkohle und RO-Membran übernehmen und wie die Leistung einer Osmoseanlage sinnvoll beurteilt wird.
Wie funktioniert eine Osmoseanlage?
Verstehen Sie das Zusammenspiel von Vorfiltration, RO-Membran und weiteren Filterstufen.
Aktivkohle oder Umkehrosmose?
Warum PAC beziehungsweise CF und RO-Membran unterschiedliche Aufgaben im Filtersystem übernehmen.
Was filtert eine Osmoseanlage?
Welche Stoffgruppen durch Umkehrosmose reduziert werden können und wo technische Grenzen liegen.
Was sagt der TDS-Wert aus?
Warum TDS für die RO-Stufe Orientierung geben kann, aber nicht den Zustand aller Filter bestimmt.
Was ist Osmosewasser?
Wie Wasser durch die RO-Membran aufbereitet wird und welche Rolle die Membranstufe übernimmt.
Wie gut ist deutsches Leitungswasser?
Warum die Zusammensetzung des Ausgangswassers für Filterbelastung und Wartung relevant sein kann.